Electocardiograph
Carewell Digital-1103L/1103LW ECG
Three channel digital electrocardiograph
Quick overview
2. 6” LCD, rea-time display of 12-lead ECG waveforms
3. Detection and alarm on lead-off and low battery capacity
4. Automatic adjustment of baseline for optimaprinting
5. Built-in ECG simulator for DEMO purpose
6. 3 kinds of operation mode: AUTO, MAN and ANA
7. 3 kinds of filters: HUM, EMG and ADS
8. Power supply: AC, DC and battery
9. 2 types lead mode: Standard and Cabrera
10. 15 ECG files can be save in the ECG
11. 1,000 ECG files can be save to SD card(Option)
12. Communication with PC (Option)
Details
Functions of ECG-1103L/1103LW are listed as in below table
MODEL |
AUTO MEAS |
AUTO ANA |
LCD SIZE |
DISPLAY |
PAPER WIDTH |
INFO |
FILE |
HELP |
RS232 |
USB |
WIRE- LESS |
SD CARD |
ECG-1103L |
Yes |
Yes |
6” |
12CH |
63MM |
Yes |
Yes |
Yes |
Yes |
Option |
No |
Option |
ECG-1103LW |
Yes |
Yes |
6” |
12CH |
80MM |
Yes |
Yes |
Yes |
Yes |
Option |
Option |
Option |
Standard configuration
- ECG-1103L/LW main unit
- Patient cable
- Chest electrode
- Limb electrode
- Thermal paper
- Paper roller
- Rechargeable battery
- Dust cover
Options
- PCECG-500A Workstation software package
- Aluminum trolley
- USB function board
Safety Standards |
MDD93/42/EEC |
Medical Device Directive |
||
IEC 60601-1: 1988 +A1:1991+A2:1995 |
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
|||
IEC 60601-2-25:1993 + A1:1999 |
Medical electrical equipment - Part 2-25: Particular requirements for the safety of electrocardiographs; Amendment 1 |
|||
IEC 60601-1-2: 2007 |
Medical electrical equipment Part 1: General requirements for safety -2 Collateral standard: Electromagnetic compatibility - Requirements and tests |
|||
EN60601-1-4-1999 |
Medical electrical equipment - Part 1-4: General requirements for safety - Collateral standard: programmable electrical medical systems |
|||
EN ISO14971-2007 |
Medical devices - Application of risk management to medical devices |
|||
Classification |
Anti-electric-shock type: |
Class І with internal power supply |
||
Anti-electric-shock degree: |
Type CF with defibrillator protection |
|||
Degree of protection against harmful ingress of water: |
Ordinary equipment (Sealed equipment without liquid proof) |
|||
Degree of safety of application in the presence of flammable gas: |
Equipment not suitable for use in the presence of flammable gas |
|||
Working Mode: |
Continuous operation |
|||
EMC: |
Group I, Class B |
|||
Dimensions |
345mm×300mm×80mm |
|||
Net Weight |
2.5kg |
|||
Display |
ECG-1103B/1103B(I): 192×64 monochrome LCD Screen ECG-1103G/1103GW(I): 3.8 inch 320×240 monochrome LCD Screen ECG-1103L/1103LW(I): 5.7 inch 320×240 monochrome LCD Screen |
|||
Environment |
|
Transport |
Storage |
Working |
Temperature |
-20℃~+55℃ |
-10℃~+40℃ |
+5℃~+40℃ |
|
Relative Humidity |
25%~95% NO Condensation |
25%~85% |
25%~85% |
|
Atmospheric Pressure |
700hPa~1060hPa |
700hPa~1060hPa |
700hPa~1060hPa |
|
Power Supply |
Mains Supply |
Rated input voltage =100V~120V(1103B (I/1103G(I/ 1103L(I/ 1103GW(I/ 1103LW(I) =220V~240V (1103B /1103G/ 1103L/ 1103GW/ 1103LW) |
||
Rated frequency = 50/60Hz |
||||
Rated input power = 35VA |
||||
External DC power supply |
Rated output voltage=12V |
|||
Rated output current=2.5A |
||||
Built-in Lithium Battery Pack |
Rated voltage = 14.4V |
|||
Discharge cut - off voltage≥11V |
||||
Rated capacity = 2000mAh |
||||
Charge mode: Constant current/voltage |
||||
Charge current (standard) <0.2C5A(400mA) |
||||
Charge voltage (standard) = (16.8±0.1V) |
||||
Cycle life ≥ 500 times |
||||
Power Consumption |
35VA(max) |
|||
Fuse |
T800mA/ AC 125V Ø5×20 (1103B (I) /1103G(I)/ 1103L(I)/ 1103GW(I) / 1103LW(I)) T400mA/AC 250V Ø5×20 (1103B /1103G/ 1103L/ 1103GW/ 1103LW) |
|||
Recorder |
Record Mode |
Thermal dot-matrix printer |
||
Recording Paper |
Rolled or folded thermo-sensitive paper |
|||
Paper Width |
80mmor 63mm |
|||
Effective width |
72mmor 56mm |
|||
Paper Speed |
6.25 mm/s, 12.5 mm/s, 25mm/s, 50mm/s (±3%) |
|||
Accuracy of data |
±5% (X- axis), ±5%( Y- axis) |
|||
HR Recognition |
Technique |
Peak-peak detection |
||
HR Range |
30BPM~215BPM |
|||
Accuracy |
±1BPM |
|||
ECG Unit |
Leads: |
12 standard leads, lead change manually/automatically |
||
Acquisition Mode: |
12 lead acquisition simultaneously |
|||
Input Circuit |
Floating, protection against defibrillator effect |
|||
A/D Resolution: |
12 bit |
|||
Time Constant: |
≥3.2s |
|||
Frequency Response: |
0.05Hz ~ 165Hz |
|||
Sensitivity: |
Auto,2.5, 5, 10, 20, 40 (mm/mV) ±5 % |
|||
Input Impedance: |
≥50MΩ(10Hz) |
|||
Input Circuit Current: |
≤50nA |
|||
Input Voltage Range |
±5 mVpp |
|||
Calibration Voltage: |
1mV±2% |
|||
Depolarization Voltage |
±500m V |
|||
Noise: |
<15μVp-p |
|||
Multichannel Crosstalk |
≤0.50mm |
|||
Filter |
EMG Filter: 25/45Hz |
|||
ADS Filter: Yes/No |
||||
HUM Filter: Yes/No |
||||
CMRR |
≥100dB |
|||
Patient Leakage Current: |
<10μA (a.c.) |
|||
Dielectric Strength: |
4000V rms |
|||
External Input/Output (Optional) |
Input (Single ended) |
Input impedance ≥100kΩ; Sensitivity10mm/V±5%; |
||
Output (Single ended) |
Output impedance≤100Ω; Sensitivity1V/mV±5%; |
|||
Communication Interface |
RS232 serial port/USB |
More products
-
Carewell Digital-1106L ECG
ECG-1106L
Six channel digital electrocardiograph -
Carewell Digital-1101G ital ECG
ECG-1101G
Single channel digital electrocardiograph -
Carewell Digital T12 ECG
T12
12 channel digital electrocardiograph