Electocardiograph
Carewell Digital T12 ECG
12 channel digital electrocardiograph
Quick overview
2. Reliable measurement and analysis result contributed by CSE database
3. Software copyright patent of “real-time age-analysis” which ensures accurate analysis results issued by the State Intellectual Property Office of the People’s Republic of China
4. 12.1” color TFT LCD display
5. Simultaneous acquisition and display of 12 channel ECG waveforms
6. Alphameric keyboard, one touch operation
7. Complete digital filters of ADS, EMG, HUM and low-pass
8. Freeze function: observe any abnormal ECG waveform
9. Pre-10-second printing function: print out any abnormal ECG waveform
10. Multi-format printouts
11. Any lead can be rhythm lead
12. Detection and alarm of lead-off and low battery capacity
13. Automatic adjustment of baseline for optimal recording
14. Built-in Help Function: electrode positioning, ECG basic knowledge, common trouble-shooting and so on
15. Clinical information such as patient ID, name, gender, age, height, weight, blood pressure, hospital name can be input
16. Maximum 2,000 ECG files can be saved. Saved ECG files can played back or printed out
17. Flexible saving interface. Saved ECG files can be displayed in image-text or list format, easy for search
18. Auto-save function: after printing, the printed ECG file will be automatically saved to flash or SD card
19. Communicate with PC for ECG data management(option)
Details
Functions of T12 are listed in below table
Model |
AUTO MEAS |
AUTO ANA |
LCD SIZE |
DISPLAY |
PAPER WIDTH |
INFO |
FILE |
HELP |
RS232 |
USB |
WIRE- LESS |
SD CARD |
T12 |
Yes |
Yes |
12.1” |
12CH |
210/216MM |
Yes |
2,000 |
Yes |
Yes |
Yes |
Option |
Yes |
Standard configuration
- T12 main unit
- Patient cable
- Chest electrode
- Limb electrode
- Thermal paper
- Paper roller
- Rechargeable battery
- Dust cover
Options
- PCECG-500A Workstation software package
- Aluminum trolley
Safety Standards |
MDD93/42/EEC |
Medical Device Directive |
||
IEC 60601-1: 1988 +A1:1991+A2:1995 GB9706.1:2007 |
Medical electrical equipment - Part 1: General requirements for safety |
|||
IEC60601-2-25: 1993 + A1:1999 GB10793:2000 |
Medical electrical equipment - Part 2-25: Particular requirements for the safety of electrocardiographs |
|||
EN 60601-1-4:1997 |
Medical electrical equipment - Part 1-4: General requirements for safety - Collateral standard: Programmable electrical medical systems |
|||
EN 60601-1-2:2003 |
Medical electrical equipment - Part 1-4: Special requirements for safety – Single/Multi-channel ECG basic features, recording and analysis |
|||
EN ISO14971:2007 |
Medical devices - Application of risk management to medical devices |
|||
YY1139:2000 |
Single/multi channel ECG |
|||
Classification |
Anti-electric-shock type: |
Class І with internal power supply |
||
Anti-electric-shock degree: |
Type CF with defibrillator protection |
|||
Degree of protection against harmful ingress of water: |
Ordinary equipment (Sealed equipment without liquid proof) |
|||
Degree of safety of application in the presence of flammable gas: |
Equipment not suitable for use in the presence of flammable gas |
|||
Working Mode: |
Continuous operation |
|||
EMC: |
Group І, Class B |
|||
Dimensions |
338mm×280mm×85mm |
|||
Net Weight |
5kgs |
|||
Display |
10.2 inches 800×480 colorLCD (T10) 12.1 inches 800×480 colorLCD (T12) |
|||
Environment |
|
Transport |
Storage |
Working |
Temperature |
-20℃~+55℃ |
-10℃~+40℃ |
+5℃~+40℃ |
|
Relative Humidity |
25%~95% |
25%~85% |
25%~85% |
|
Atmospheric Pressure |
700hPa ~1060hPa |
700hPa ~1060hPa |
700hPa ~1060hPa |
|
Power Supply |
AC power Supply |
Rated input voltage =100V~240V |
||
Rated frequency = 50/60Hz |
||||
Rated input power =80VA |
||||
External DC power supply |
Rated output voltage=19V |
|||
Rated output current=3.5A |
||||
Built-in Lithium Battery Pack |
Rated voltage = 14.4V |
|||
Discharge cut - off voltage≥11V |
||||
Rated capacity = 4400mAh |
||||
Charge mode: Constant current/voltage |
||||
Charge current (standard) <0.3C5A(1320mA) |
||||
Charge voltage (standard) = (16.8±0.1V) |
||||
Cycle life ≥ 500 times |
||||
Power Consumption |
70VA(max) |
|||
Fuse |
T2A/AC 250V Ø5×20 |
|||
Recorder |
Record Mode |
Thermal dot-matrix printer |
||
Recording Paper |
Rolled or folded thermo-sensitive paper |
|||
Paper Width |
210/216 mm roll paper, 210*90mm Z-fold paper |
|||
Effective width |
200/206 mm roll paper, 200*90 mm Z-fold paper |
|||
Paper Speed |
5 mm/s, 6.25 mm/s, 10mm/s, 12.5 mm/s, 25mm/s, 50mm/s(±3%) |
|||
HR Recognition |
Technique |
Peak-peak detection |
||
HR Range |
30BMP~215BMP |
|||
Accuracy |
±1 BPM |
|||
ECG Unit |
Leads: |
12 standard leads, lead change manually/automatically |
||
Acquisition Mode: |
12 lead acquisition simultaneously |
|||
Input Circuit |
Floating, protection against defibrillator effect |
|||
A/D Resolution: |
12 bit |
|||
Time Constant: |
≥3.2s |
|||
Frequency Response: |
0.05Hz ~ 165Hz |
|||
Sensitivity: |
Auto,2.5, 5, 10, 20,40 (mm/mV) ±5 % |
|||
Input Impedance: |
>50MΩ(10Hz) |
|||
Input Circuit Current: |
≤50Na |
|||
Input Voltage Range |
±5 mVpp |
|||
Calibration Voltage: |
1mV±2% |
|||
Depolarization Voltage |
±700m V |
|||
Noise: |
<15μVp-p |
|||
Filter |
EMG Filter: 25Hz, 35Hz, 45Hz |
|||
ADS Filter: Yes/No |
||||
HUM Filter: 50Hz, 60Hz |
||||
CMRR |
≥100dB |
|||
Patient Leakage Current: |
<10μA (a.c.) |
|||
Dielectric Strength: |
4000V rms |
|||
External Input/Output (Optional) |
Input (Single ended) |
Input impedance≥100kΩ; Sensitivity10mm/V±5%; |
||
Output (Single ended) |
Output impedance≤100Ω; Sensitivity1V/mV±5%; |
|||
Communication Interface |
RS232 serial port/USB |
More products
-
Carewell Digital-1103L/1103LW ECG
ECG-1103L/1103LW
Three channel digital electrocardiograph -
Carewell Digital-1101G ital ECG
ECG-1101G
Single channel digital electrocardiograph -
Carewell Digital 1112L ECG
ECG-1112L
12 channel digital electrocardiograph